We don't just pull for pleasure but for your safety!
ULTIMATE PEACE OF MIND IS KNOWING THAT YOUR WORKING AT HEIGHT RESPONSIBILITIES ARE TOTALLY TAKEN CARE OF
WE PROVIDE SERVICES TO
Design
Install
Certify
We don't just pull for pleasure but for your safety!
WE PROVIDE SERVICES TO: Design - Install - Certify
Anchors installed directly to steel
Vertical wall Parapet chemical anchors
Rooftop floor anchors
Re- Belay anchor point
Deviation anchor point
Vertical wall anchor points
Self Identified anchors
Aiding anchors
Edge protections
Temporary dead-weight anchors
Custom edge brackets to avoid pressure of edge
WE SAVE LIVES
NDT TESTING ON ACCESS SYSTEMS
ACCESS SOLUTION DESIGN
IN-HOUSE CUSTOM FABRICATION
SYSTEM INSTALLATION
MAINTENANCE & RECERTIFICATION
ANCHOR PORTFOLIO MANAGEMENT
ANCHOR MANAGEMENT
ONLINE BUILDING MANAGEMENT PLATFORM FOR ANCHOR POINT RECORD KEEPING AND COMPLIANCE
Fall protection & access equipment maintenance management
ANCHOR POINT LAYOUT PLAN OF EACH BUILDING WITH EXPIRY DATES
Sites, buildings and assets view Alert flags when recertification required
INCORPORATE EXISTING OR OLD ANCHORS INTO SYSTEM, DOESN'T MATTER WHO INSTALLED IT
Overview of positioning of existing anchorpoints and no go zone that still require anchors
SYSTEM CERTIFICATION SERVICE
Managed by AP using accredited installers Recertification automatically, yearly and new updated on system to view at anytime
JOB & TASK MANAGEMENT
Building manager login to verify anchor certifications. Download any documentation required to present contractors who will be using the anchors per site
METHOD STATEMENTS MANUALS
Protocol for using anchors
Maintenance and Recertification
Is essential for peak performance and smooth, fail-safe operation
OUR 6 POINT CERTIFICATION VALIDATION
• Actual date & time stamped images ( of each and every anchor pull test performed as the most important part as proof that a anchor was tested to the said weight per certificate, this also proof when it was tested, and lastly proofs what time it was tested, as each new test must have a time lapse of at least 3min between each image, and for retesting a time-laps of at least 20sec.
• Pull tester calibration certificate that is actually used on the anchor pull test – image as proof supports this.
• Installation technician certification that proofs he is qualified to perform the installation.
• Anchor pull test technician certification that proofs he is qualified to perform the test.
• Product certifications from manufacturer.
• Rigging forces applied when working, that calculate the forces in case of an fall to indicate that the anchors are save and can withstand the fall factor